Condensates

Application:

Gas condensates are comprised heavier compounds than Butan which are like liquid in an atmospheric condition. These valuable compounds will be transferred to tanks just after vapor pressure fixing and dew point settings and then after storing it will be offered to international markets.

CONDENSATE

METHOD USED UNLESS OTHERWISE STATED) RESULT
SHORE TANKS SAMPLE (INDIVIDUAL) 1105 1106
DENCITY @ 15.0 C KG/M3 ASTM D-1298 817.6 817.6
DISTILLATION D-86 --- ---
I.B.P TEMP ^C 60 59
10% RECOVERY TEMP ^C 123 122
20% RECOVERY TEMP ^C 151 151
50% RECOVERY TEMP ^C 261 260
90% RECOVERY TEMP ^C 390 390
F.B.P ^C

RESIDUE %VOL --- ---
LOSS %VOL --- ---
TOTAL SULPHUR %WT D-1552 0.55 0.55
CORROSION 3 HRS 50 ^C D-130 (NO 1 STRIP)
VAPOUR PRESSURE LB/IN2 D-323 --- ---
COLOUR D-1500 7.5 7.5
PARAFFINS CONTENT %VOL D-1319 --- ---
OLEFFINS CONTENT %VOL D-1319 --- ---
NAPHTHENES CONTENT %VOL D-1319 --- ---
AROMATICS CONTENT %VOL D-1319 --- ---
LEAD (PB)P.P.B UOP 350-68T

C/H RATIO (ESTIMATED) 6.28 6.28
GUM EXISTENT (AIR JET)mg/100ml D-381 --- ---
WATER AND SEDIMENT %VOL D-2709 0.005 0.005
Origin: Middle East


CONDENSATE

ANALYSIS TEST METHOD RESULT
SHORE
SPECIFIC GRAVITY 60/60 ASTM. D-4052  0.7275
API GRAVITY CALCULATED 63
WATER CONTENT ASTM. D-1533  *****
DISTILLATION D-86  *****
I. B. P
35
5% RECOVERED
46
10%
55
30%
80
50%
102
70%
127
90%
180
95%
215
F. B. P
255
LOSS%
1.4
RESIDUE%
1.6
R. S. H (PPM.) D-1219  158
R. V. P (PSI. @ 100 of) D-323  7.8